Search

In Stock

Immunoaffinity Column for Fumonisins B1,B2,B3

The immunoaffinity column can selectively adsorb fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for LC- MS/MS analysis after concentrating with nitrogen gas and resuspended or for HPLC analysis after derivatization.

Affinity columns can be used in combination with HPLC or LC- MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.

Order No.: HCM0825B

Specification: 3mL,25T, 5000ng

  1. Purpose:

The immunoaffinity column can selectively adsorb fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for LC- MS/MS analysis after concentrating with nitrogen gas and resuspended or for HPLC analysis after derivatization.

Affinity columns can be used in combination with HPLC or LC- MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.

2. Overview:

Fumonisin is a metabolite produced by Fusarium fungi. It has acute and chronic toxicities and is species-specific and organ specific. Studies have found that high concentrations of fumonisin can cause acute species- specific toxicity symptoms in many domestic and laboratory animals, such as equine leukoencephalomalacia, porcine pulmonary edema, and liver and kidney diseases in sheep. The toxin has also been found to be related to esophageal and liver cancer in humans.

3. Principle:

The basis of the measurement is the antigen-antibody reaction. Antibodies are connected to the column and the fumonisin in the sample is extracted, filtered, and diluted, and then passed slowly through the Ochratoxin A immunoaffinity column. The toxins bind to the antibodies in the column and the immunoaffinity column is then washed to remove other unrelated substances that have not been bound. Fumonisin is then eluted with methanol and injected into an analytical instrument for detection.

4. Components of the kit:

Each kit contains fumonisin immunoaffinity columns of various specifications and 1 instruction manual.

5. Necessary items not provided in the box:

  • Equipment
  • HPLC
  • Derivatization device: such as optical derivatization device, photochemical derivatization device, iodine derivatizationdevice
  • Centrifuge capable of at least 3,000-4,000 xg
  • Nitrogen gas evaporatorapparatus
  • Nitrogen gas tank and pressureregulator
  • Air-pressure controllerbracket
  • Airpump
  • Balance with 0.01greadability
  • High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
  • Grinder
  • Sievingscreen:2-mm
  • Graduated cylinder: 100 mL/10mL
  • Funnel: 50mL
  • Syringe: 10 mL/20mL
  • Pipette: 1 mL and pipettetips
  • Homogenization flask (or 250-mL conical flask withpestle)
  • Sample bottles andtubes
  • Rapid qualitative filterpaper
  • Microfiber filter paper (e.g., Whatman934-AH)
  • Column holder and syringe connector plug (for use with immunoaffinity columns)
  • 5.1 Reagents
    • Methanol (CH3OH): Analytical grade forextraction/Chromatography grade for elution
    • Disodium hydrogen phosphate dodecahydrate (Na2HPO4∙ 12H2O):Analytical Grade
    • Acetic acid (CH3COOH): Analyticalgrade
    • Acetonitrile (CH3CN): Analytical grade forextraction/Chromatography grade for elution
    • Potassium dihydrogen phosphate (KH2PO4): AnalyticalGrade
    • Sodium chloride (NaCl): AnalyticalGrade
    • TWEEN-20 (C58H114O26): AnalyticalGrade
    • Hydrochloric acid (HCl): AnalyticalGrade
    • Sodium hydroxide (NaOH): AnalyticalGrade
    • Potassium chloride (KCl): AnalyticalGrade
    • Distilled or deionizedwater

    6. Note:

    • Allowthe immunoaffinity column to return to room temperature (22 to 25°C) before
    • The affinity column should be stored at 2 to 8°C, do not
    • Dot use any expired immunoaffinity
    • The sample volume can be increased or decreased appropriately as required, and the volume of the extraction solution should be adjusted
    • Columncapacity
    • Toxin nameColumn Capacity: ng
      FB1 

      5000

      FB2
      FB3
Quantity

1-10, 11-100, 101-1000, 1001-10000

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Aflatoxin M1 Qualitative Lateral Flow Rapid Test Kit

Aflatoxin M1 Qualitative Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of aflatoxin M1 in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Tetracyclines ELISA Test Kit for Animal Tissue, Seafood and Egg

Qualitative or quantitative analysis of tetracycline, oxytetracycline, aureomycin, doxycycline in animal tissue, seafood and egg, etc.Meizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart