Search

In Stock

Immunoaffinity Column for Mycotoxin Deoxynivalenols (DON/15-ADON)

Order No.: HCM8150B

Product Properties: DON: 2000ng; 15-A-DON: 2000ng

Specification: 3mL, 50T

1. Purpose:

The immunoaffinity column can selectively adsorb Deoxynivalenol (Vomitoxin, DON) and 15-acetyldeoxynivalenol (15-ADON), and has a highly targeted purification effect. Samples that have passed through the column for purification may be used in HPLC, LC-MS/MS and other devices for analysis after concentrating with nitrogen gas.

Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.

2. Overview:

DON belongs to the single-endomycin family of molds and is produced by certain Fusarium fungi. 15-ADON is derivative of DON. These toxins are mostly distributed in grain seeds such as wheat, barley, and corn. Due to their high cytotoxicity and immunosuppressive properties, they pose a health threat to humans and animals.

3. Principle:

The basis of the measurement is the antigen-antibody reaction. Antibodies are connected to the column and the aflatoxin in the sample is extracted, filtered, and diluted, and then passed slowly through the aflatoxin immunoaffinity column. The toxins bind to the antibodies in the column and the immunoaffinity column is then washed to remove other unrelated substances that have not been bound. Deoxynivalenol is then eluted with methanol and injected into an analytical instrument for detection.

4. Components of the kit:

Each kit contains Deoxynivalenol immunoaffinity columns of various specifications and 1 instruction manual.

5. Necessary items not provided in the box:

  • Equipment
  • HPLC/LC-MS/MS
  • Nitrogen gas evaporatorapparatus
  • Nitrogen gas tank and pressureregulator
  • Air-pressure controller bracket
  • Air pump
  • Balance with 0.01greadability
  • High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
  • Grinder
  • Sievingscreen:1-mm
  • Graduated cylinder: 100 mL/10mL
  • Funnel: 50mL
  • Syringe: 10 mL/20mL
  • Pipette: 1 mL and pipettetips
  • Homogenization flask (or 250-mL conical flask withpestle)
  • Vials andtubes
  • Rapid qualitative filterpaper
  • Microfiber filter paper (e.g., Whatman934-AH)
  • Column holder and syringe connector plug (for use with immunoaffinitycolumns)

5.2 Reagents

  • Methanol (CH3OH): Analytical grade forextraction/chromatography grade for elution
  • Acetonitrile (CH3CN): AnalyticalGrade
  • Sodium chloride (NaCl): AnalyticalGrade
  • Potassium dihydrogen phosphate (KH2PO4): AnalyticalGrade
  • Disodium hydrogen phosphate dodecahydrate(Na2HPO412H2O): Analytical Grade
  • Polyethylene glycol (8000Da, HO(CH2CH2O)nH): AnalyticalGrade, to improve filtration speed, if the supernatant is obtained by centrifugation , this reagent can be
  • TWEEN-20 (C58H114O26): AnalyticalGrade
  • Hydrochloric acid (HCl): AnalyticalGrade
  • Sodium hydroxide (NaOH): AnalyticalGrade
  • Potassium chloride (KCl): AnalyticalGrade
  • Distilled or deionizedwater

6. Note:

  • Allow the immunoaffinity column to return to room temperature (22 to 25°C) before
  • The affinity column should be stored at 2 to 8°C, do not
  • Dot use any expired immunoaffinity
  • The sample volume can be increased or decreased appropriately as required, and the volume of the extraction solution should be adjusted
  • Columncapacity
Toxin nameColumn Capacity:(ng)
DON2000
15-ADON2000

When the content of the toxin in the sample divided by the dilution factor is higher than the column capacity, it is necessary to reduce the volume of the sample solution appropriately, and retest.

  • The pH of the loading solution of the affinity column should be within the range of 6 to 8. If it deviates from this range, the pH should be adjusted with dilute hydrochloric acid or dilute sodium hydroxide.
  • Maintaining consistency (such as polarity, pH, and concentration) between the test solvent loaded into any analytical instrument and the mobile phase can help eliminate any adverse solvent
  • WARNING: Aflatoxin is toxic and carcinogenic; protective equipment such as gloves and masks should always be used during handling.
  • Vesselsand tools used to handle toxin solutions should be

completely immersed in a sodium hypochlorite solution (5% v/v) overnight.

  • Ensure the LC-MS/MS is clean and the tubing is primed appropriately for each
  • Follow appropriate instrument precautions if using
Quantity

1-10, 11-100, 101-1000, 1001-10000

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Aflatoxin M1 Qualitative Lateral Flow Rapid Test Kit

Aflatoxin M1 Qualitative Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of aflatoxin M1 in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Tetracyclines ELISA Test Kit for Animal Tissue, Seafood and Egg

Qualitative or quantitative analysis of tetracycline, oxytetracycline, aureomycin, doxycycline in animal tissue, seafood and egg, etc.Meizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart