Immunoaffinity Column for Mycotoxin Ochratoxin A

The immunoaffinity column can selectively adsorb Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC analysis or for LC-MS/MS analysis after being concentrated with nitrogen gas and resuspended.

Affinity columns can be used in combination with HPLC to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.

Order No.: HCM0725B

Package: 3mL,50T

Coposition: 100 ng

1. Overview:

Ochratoxin A (OTA) is a toxic metabolite produced by some species of Aspergillus and Penicillium,it is a mycotoxin with high kidney and liver toxicities, and has teratogenic, mutagenic, and carcinogenic effects.

2. Principle:

The basis of the measurement is the antigen-antibody reaction. Antibodies are connected to the column and the Ochratoxin A in the sample is extracted, filtered, and diluted, and then passed slowly through the Ochratoxin A immunoaffinity column. The toxins bind to the antibodies in the column and the immunoaffinity column is then washed to remove other unrelated substances that have not been bound. Ochratoxin A is then eluted with methanol and injected into an analytical instrument for detection.

3. Components of the kit:

Each kit contains Ochratoxin A immunoaffinity columns of various specifications and 1 instruction manual.

4. Necessary items not provided in the box:

  • Equipment
  • HPLC
  • Centrifuge capable of at least 3,000-4,000RPM
  • Nitrogen gas evaporatorapparatus
  • Nitrogen gas tank and pressureregulator
  • Air-pressure controllerbracket
  • Airpump
  • Balance with 0.01greadability
  • High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
  • Grinder
  • Sievingscreen:2-mm
  • Graduated cylinder: 100 mL/10mL
  • Funnel: 50mL
  • Syringe: 10 mL/20mL
  • Pipette: 1 mL and pipettetips
  • Homogenization flask (or 250-mL conical flask withpestle)
  • Vials andtubes
  • Rapid qualitative filterpaper
  • Microfiber filter paper (e.g. Whatman 934-AH)
  • Columnholder and syringe connector plug (for use with immunoaffinity columns)

5.1 Reagents

  • Disodium hydrogen phosphate dodecahydrate (Na2HPO4∙ 12H2O):Analytical Grade
  • Acetic acid (CH3COOH): ChromatographyGrade
  • Potassium dihydrogen phosphate (KH2PO4): AnalyticalGrade
  • Sodium chloride (NaCl): AnalyticalGrade
  • TWEEN-20 (C58H114O26): AnalyticalGrade
  • Hydrochloric acid (HCl): Analytical Grade
  • Sodium hydroxide (NaOH): AnalyticalGrade
  • Potassium chloride (KCl): AnalyticalGrade
  • Sodium Bicarbonate (NaHCO3):Analytical Grade
  • Distilled or deionizedwater

Note:

Methanol (CH3OH): Analytical grade forextraction/Chromatography grade for elution

Allow the immunoaffinity column to return to room temperature (22 to 25°C) before

The affinity column should be stored at 2 to 8°C, do not

Dot use any expired immunoaffinity

The sample volume can be increased or decreased appropriately as required, and the volume of the extraction solution should be adjusted

Column capacity: 100 ng, when the content of the toxin in the sample divided by the dilution factor is higher than the column capacity, it is necessary to reduce the volume of the sample solution appropriately, and

The pH of the loading solution of the affinity column should be within the range of 6 to 8. If it deviates from this range, the pH should be adjusted with dilute hydrochloric acid or dilute sodium hydroxide.

Maintaining consistency (such as polarity, pH, and concentration) between the test solvent loaded into any analytical instrument and the mobile phase can help eliminate any adverse solvent

WARNING: Ochratoxin A is toxic and carcinogenic; protective equipment such as gloves and masks should always be used during handling.

Vessels and tools used to handle toxin solutions should be completely immersed in a sodium hypochlorite solution (5% v/v) overnight.

Ensure the LC-MS/MS is clean and the tubing is primed appropriately for each

Follow appropriate instrument precautions if using

 

Quantity

1-10, 11-100, 101-1000, 1001-10000

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Aflatoxin M1 Qualitative Lateral Flow Rapid Test Kit

Aflatoxin M1 Qualitative Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of aflatoxin M1 in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Tetracyclines ELISA Test Kit for Animal Tissue, Seafood and Egg

Qualitative or quantitative analysis of tetracycline, oxytetracycline, aureomycin, doxycycline in animal tissue, seafood and egg, etc.Meizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart