Immunoaffinity Column for Vitamin B12 Dairy Nutrients IAC Column

The immunoaffinity column can selectively adsorb vitamin B12  from the sample solution, thereby purifying the sample, and the samples that have be purified after passing through the column can be used in HPLC or LC-MS/MS analysis.

Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.

Order No.: QC0139

Product Properties: 1000ng

Specification: 3mL,25T

Matrix: Vitamin tablets, high-protein functional drinks and premixes, carbonated drinks and juices, infant formula milk powder.

1. Overview:

VB12, or cobalamin, is one of eight B vitamins, It is important in the normal functioning of the nervous system via its role in the synthesis of myelin, and in the maturation of red blood cells in the bone marrow.

2. Principle:

The basis of the measurement is the antigen-antibody reaction. Antibodies are connected to the column and the VB12 in the sample is extracted, filtered, and diluted, and then passed slowly through the immunoaffinity column. The VB12 bind to the antibodies in the column and the immunoaffinity column is then washed to remove other unrelated substances that have not been bound. VB12 is then eluted with methanol and injected into an analytical instrument for detection.

3. Components of the kit:

Each kit contains VB12 immunoaffinity columns and 1 instruction manual.

4. Necessary items not provided in the box:

  • Equipment
  • HPLC/LC-MS/MS
  • Nitrogen gas evaporator apparatus
  • Nitrogen gas tank and pressure regulator
  • Air-pressure controller bracket
  • Air pump
  • Balance with 0.01g readability
  • High-speed freezing centrifuge (can be set to 4°C, 8,000 rpm)
  • Centrifuge tube:50-mL
  • Constant temperature incubator or water bath (can be set to 25–100℃)
  • High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
  • Ultrasonic cleaner
  • Grinder
  • pH meter (or pH test paper)
  • Volumetric flask: 100 mL/50 mL
  • Syringe: 10 mL/20 mL
  • Homogenization flask (or 250-mL conical flask with pestle)
  • Vials and tubes
  • Syring:10mL/50mL
  • Pipette: 1 mL and pipette tips
  • Column holder and syringe connector plug (for use withimmunoaffinity columns)

5.2 Reagents

  • Methanol (CH3OH): Chromatography Grade
  • Acetonitrile (CH3CN): Chromatography Grade
  • Sodium hydroxide (NaOH): Analytical Grade
  • Potassium chloride (KCl): Analytical Grade
  • Formic acid (HCOOH): Chromatography Grade
  • Acetic Acid (CH3COOH): Analytical Grade
  • Sodium acetate (CH3COONa): Analytical Grade
  • Potassium cyanide (KCN): Analytical Grade
  • Hydrogen chloride (HCl): Analytical Grade
  • Trifluoroacetic acid (CF3COOH): Analytical Grade
  • Pepsin
  • Alpha-amylase
  • Distilled or deionized water

5. Note:

  • Allow the immunoaffinity column to return to room temperature (22 to 25°C) before use.
  • The affinity column should be stored at 2 to 8°C, do not freeze.
  • Dot use any expired immunoaffinity column.
  • Column capacity:1000 ng, when the content of the VB12 in the sample divided by the dilution factor is higher than the column capacity, it is necessary to reduce the volume of the sample solution appropriately, and retest.
  • The pH of the loading solution of the affinity column should be within the range of 6 to 8. If it deviates from this range, the pH should be adjusted with dilute hydrochloric acid or dilute sodium hydroxide.
  • Sensitivity: To obtain the best column efficiency and quantification of the detection and analysis system, it is recommended to load samples containing 100ng-500ng of VB12 on the column. Do not load samples approaching or exceeding 1000ng of VB12.
  • The VB12 immunoaffinity column is depending on gravity. No
  • external pressure is applied during use, and the purification operation is completed by the gravity of the buffer and the sample. Recommended flow rate is 1.5-2 mL/min.
  • WARNING: Potassium cyanide is toxic and carcinogenic; protective equipment such as gloves and masks should always be used during handling. Sodium hypochlorite solution can be added to the waste liquid, and then discharged after treatment
  • Vessels and tools used to handle toxin solutions should be completely immersed in a sodium hypochlorite solution (4% v/v) overnight. A certain amount of sodium hydroxide can be appropriately added to this solution to ensure the alkaline environment of the solution. After 24 hours, use test paper for cyanide to detect.
  • Keeping the solvent and mobile phase consistent with the instrument detection can eliminate the effect of solvent effects.
Quantity

1-10, 11-100, 101-1000, 1001-10000

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Aflatoxin M1 Qualitative Lateral Flow Rapid Test Kit

Aflatoxin M1 Qualitative Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of aflatoxin M1 in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Tetracyclines ELISA Test Kit for Animal Tissue, Seafood and Egg

Qualitative or quantitative analysis of tetracycline, oxytetracycline, aureomycin, doxycycline in animal tissue, seafood and egg, etc.Meizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart