Search

In Stock

Sulfamethazine ELISA Test Kit for Dairy, Meat, Serum, Urine and Feed

Procedure Overview

The method is based on a competitive, two-step colorimetric enzyme-linked immunosorbent assay (ELISA). The target analyte has been coated to the plate wells. During analysis, sample is added along with a primary antibody specific to the target analyte. If the target analyte is present in the sample, it will compete for the antibody, thereby preventing the antibody from binding to the analyte coated to the plate well. A secondary antibody, tagged with a peroxidase enzyme, targets the primary antibody that is complexed to the analyte coated on the plate wells. The resulting color intensity, after addition of TMB substrate, has an inverse relationship to the target analyte concentration in the sample.

Order No: ME08DER

KIT CONTENTS, STORAGE, & SHELF LIFE

ELISA Test Kit has the capacity for 96 determinations or testing of 42 samples in duplicate (assuming 12 wells for standards). Return any unused microwells to the foil bag and reseal them with the desiccant provided in the original package. Store the entire kit at 2–8°C. Do not use this product past the expiration date indicated on the Certificate of Analysis.

Kit ContentsQuantityStorage
Sulfamethazine-Coated Plate1 x 96-well plate2–8°C
Sulfamethazine Standards 
Negative control 0.8 mL2–8°C
0.25 ng/mL 0.8 mL2–8°C
0.5 ng/mL 0.8 mL2–8°C
1.0 ng/mL 0.8 mL2–8°C
5.0 ng/mL 0.8 mL2–8°C
10 ng/mL 0.8 mL2–8°C
Spiking Solution 
100 ng/mL (red cap tube)0.8 mL2–8°C
Sulfamethazine Antibody #112 mL2–8°C
100X HRP-Conjugated Antibody #2250 µL2–8°C
20X Wash Solution28 mL2–8°C
Antibody #2 Diluent20 mL2–8°C
TMB Substrate12 mL2–8°C
10X Sample Extraction Buffer25 mL2–8°C

Required Materials Not Provided with the Kit

  • Microtiter Plate Reader with 450 nm primary filter and optional 630 nm differentialfilter
  • TissueHomogenizer
  • VortexMixer
  • 10, 20, 100 and 1000 µLPipettes
  • Distilled or deionizedwater
  • Multi-Channel Pipette: 50–300 µL(Optional)
  • Reagent Resevoir(Optional)
  • Incubator capable of at least75°C
  • Centrifuge capable of 4,000 xg
  • Carrez I: 0.36 M Potassium Hexacyanoferrate (II)Trihydrate
  • Carrez II: 12M concentrated hydrochloric acid(HCl)

SENSITIVITY

Sample TypeDetection Limit (ng/g or ppb)
Beef1
Pork1
Meat, Liver, Kidney2
Feed1
Milk10
Milk Powder11.5
Serum/Plasma2.5
Urine1.25

SPECIFICITY

AnalyteCross-Reactivity (%)
Sulfamethazine100

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Aflatoxin M1 Qualitative Lateral Flow Rapid Test Kit

Aflatoxin M1 Qualitative Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of aflatoxin M1 in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Tetracyclines ELISA Test Kit for Animal Tissue, Seafood and Egg

Qualitative or quantitative analysis of tetracycline, oxytetracycline, aureomycin, doxycycline in animal tissue, seafood and egg, etc.Meizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart