Search

In Stock

Animal Tissue and Feed Illegal Additive Clenbuterol ELISA Test Kit

Qualitative or quantitative analysis of Clenbuterol in swine urine, animal tissue, serum, and feed.

Order No.: ME29AER

【Summary】

Clenbuterol, a beta-agonist, it can be used in livestock in order to promote growth and improve the meat-fat-ratio. Yet, the use of Clenbuterol has consequences: drug residues remain in meat and milk from treated animals.

The use of clenbuterol has been banned in meat since 1991 in the US and since 1996 in the European Union. The drug is banned due to health concerns about symptoms noted in consumers. These include increased heart rate, muscular tremors, headaches, nausea, fever, and chills.

【Principles】

Clenbuterol ELISA Kit is an indirect competitive enzyme-labeled immunoassay. The Clenbuterol antigen is precoated on the wells. The precoated antigen compete the Clenbuterol antibody (Antibody Solution) with Clenbuterol in the sample, Clenbuterol antibody binds to the Clenbuterol Enzyme Conjugate. After the color development of TMB Substrate, the absorbance value of the sample is negatively correlated with the Clenbuterol contained in it. Compared with the standard curve and multiplied by its corresponding dilution factor, the content of Clenbuterol in the sample can be calculated.

【Cross Reactivity】

Clenbuterol 100%

Terbutaline <1%

Fenoterol <1%

Mabuterol <1%

Cimaterol <1%

Bromobuterol <1%

【Materials Required But Not Provided】

  1. Devices:

—- Microplate Reader (450nm/630nm filter)

—- Constant Temperature Incubator (Optional)

—- Homogenizer

—- Vortex

—- Centrifuge

—- Balance (sensibility: 0.01g)

—- Graduated Pipette: 10mL

—- Rubber Bulb Syringe

—- Centrifuge tube: 5mL/7mL, 50mL

—- Micropipette: Single channel pipette (10-100µL, 100-1000µL)

Multi-channel pipette (30-300µL)

  1. Reagent:

—- Deionized Water

—- Methanol (AR)

—- Trichloroacetic Acid (CCl3COOH) (AR)

—- 18M Concentrated Sulfuric Acid (H2SO4)

【Provided Materials and Reagent】

Component 96 wells
Antigen Coated Plate96T
5 vials of Standard1mL each
High Concentration Standard (100ppb)1mL
Enzyme Conjugate6mL
Antibody Solution6mL
Substrate A6mL
Substrate B6mL
Concentrated Wash Buffer (10×)40mL
Concentrated Sample Diluting Buffer Ⅰ50mL
Concentrated Sample Diluting Buffer Ⅱ15mL
Package Insert1
Testing Report1
Plate Cover Sheet2

Note: The concentrations of the standards are 0ppb, 0.1ppb, 0.3ppb, 0.9ppb, 2.7ppb.

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Beta-lactams, Tetracyclines, Streptomycin and Chloramphenicol Rapid Test Kit

The Beta-lactams, Tetracyclines, Streptomycin and Chloramphenicol Rapid Test Kit, 4-in-1 Rapid Test Kit is a Lateral Flow assay that determines the residues for the presence of target antibiotic residues in raw milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Total Aflatoxins Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin and is intended for use in grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart