Bestsellers in Pre-Treatment
Aflatoxin M1 Immunoaffinity Column
Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T
Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A
The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T
Immunoaffinity Column for Aflatoxin B1,B2,G1,G2
The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio and improve the accuracy of the detection method.
Immunoaffinity Column for Deoxynivalenols (DON/3-ADON/15-ADON)
The immunoaffinity column can selectively adsorb Deoxynivalenol (Vomitoxin,DON),3-acetyldeoxynivalenol,(3-ADON),15-acetyldeoxyniv alenol (15-ADON), and has a highly targeted purification effect. Samples that have passed through the column for purification may be used in HPLC, LC-MS/MS and other devices for analysis after concentrating with nitrogen gas.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM3025B
Dairy Immunoaffinity Column for Vitamin B12 Nutrients IAC Column
The immunoaffinity column can selectively adsorb vitamin B12 from the sample solution, thereby purifying the sample, and the samples that have be purified after passing through the column can be used in HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: QC0092Product Properties: 1000ngSpecification: 3mL, 50TMatrix: Vitamin tablets, high-protein functional drinks and premixes, carbonated drinks and juices, infant formula milk powder.
Immunoaffinity Column for Fumonisins B1,B2,B3
The immunoaffinity column can selectively adsorb fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for LC- MS/MS analysis after concentrating with nitrogen gas and resuspended or for HPLC analysis after derivatization.Affinity columns can be used in combination with HPLC or LC- MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0825BSpecification: 3mL,25T, 5000ng
Showing 1–12 of 72 results
Aflatoxin M1 Immunoaffinity Column
Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T