Search

In Stock

Immunoaffinity Column 3-in-1 Comb Aflatoxin B1, Zearalenone and T-2 Toxin

The immunoaffinity column can selectively adsorb aflatoxin B1, Zearalenone and T-2 Toxin from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.

Order No.: HCM6525B/HCM6550B

1. Principle:

The basis of the measurement is the antigen-antibody reaction. Antibodies are connected to the column and the toxin in the sample is extracted, filtered, and diluted, and then passed slowly through the immunoaffinity column. The toxins bind to the antibodies in the column and the immunoaffinity column is then washed to remove other unrelated substances that have not been bound. The toxins are then eluted with eluent and injected into an analytical instrument for detection.

2. Components of the kit:

Each kit contains 3-in-1 Aflatoxin B1/Zearalenone /T-2 Toxin immunoaffinity columns and 1 instruction manual.

3. Necessary items not provided in the box:

  • Equipment
  • LC-MS(LC-MS/MS)
  • Centrifuge capable of at least 3,000-4,000 xg
  • Nitrogen gas evaporatorapparatus
  • Nitrogen gas tank and pressureregulator
  • Air-pressure controller bracket
  • Air pump
  • Balance with 0.01greadability
  • High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
  • Grinder
  • Sievingscreen:2-mm
  • Graduated cylinder: 100 mL/10mL
  • Funnel: 50mL
  • Syringe: 10 mL/20mL
  • Pipette: 1 mL and pipettetips
  • Homogenization flask (or 250-mL conical flask withpestle)
  • Vials andtubes
  • Rapid qualitative filterpaper
  • Microfiber filter paper (e.g., Whatman934-AH)
  • Column holder and syringe connector plug (for use with immunoaffinitycolumns)

4.2 Reagents

  • Methanol (CH3OH): Chromatographicgrade
  • Acetic acid (CH3COOH): ChromatographyGrade
  • Acetonitrile (CH3CN): AnalyticalGrade
  • Sodium chloride (NaCl): AnalyticalGrade
  • Sodium hydroxide (NaOH): AnalyticalGrade
  • Hydrochloric acid (HCl): AnalyticalGrade
  • Potassium dihydrogen phosphate (KH2PO4): AnalyticalGrade
  • Disodium hydrogen phosphate dodecahydrate(Na2HPO412H2O): Analytical Grade
  • Potassium chloride (KCl): AnalyticalGrade
  • Distilled/deionizedwater

4. Note:

  • Allow the immunoaffinity column to return to room temperature (22 to 25°C) before
  • The affinity column should be stored at 2 to 8°C, do not
  • Dot use any expired immunoaffinity
  • The sample volume can be increased or decreased appropriately as required, and the volume of the extraction solution should be adjusted
  • Columncapacity:
Toxin nameColumn Capacity: ng
ZEN2000
AFT B1300
T-2 Toxin2000

When the content of the toxin in the sample divided by the dilution factor is higher than the column capacity, it is necessary to reduce the volume of the sample solution appropriately, and retest.

  • The pH of the loading solution of the affinity column should be within the range of 6 to 8. If it deviates from this range, the pH should be adjusted with dilute hydrochloric acid or dilute sodium
  • Maintaining consistency (such as polarity, pH, and concentration) between the test solvent loaded into any analytical instrument and the mobile phase can help eliminate any adverse solvent
  • WARNING: Aflatoxin, Zearalenone andT-2 Toxin are toxic and carcinogenic; protective equipment such as gloves and masks should always be used during
  • Vessels and tools used to handle toxin solutions should be completely immersed in a sodium hypochlorite solution (5% v/v) overnight.
  • Ensure the LC-MS/MS is clean, and the tubing is primed appropriately for each

5. Storage conditions and period of validity

Storage Conditions: 2 to 8°C

Expiry Date: this product is valid for a period of 18 months.

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Milk Clindamycin Rapid Test Kit

The Clindamycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of clindamycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Corn and Feed Mycotoxin Fumonisins ELISA Test Kit

The Fumonisins(FB) ELISA Kit is an indirect competitive ELISA kit for the quantitative analysis of fumonisins in feed, corn, and corn by- products.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

 

Back to Top
Product has been added to your cart