Background:
Streptomycin is an antibiotic (antimycobacterial) drug, the first of a class of drugs called aminoglycosides to be discovered, and it was the first effective treatment for tuberculosis. It is derived from the actinobacterium Streptomyces griseus. Streptomycin is a bactericidal antibiotic. Adverse effects of this medicine are ototoxicity, nephrotoxicity, fetal auditory toxicity, and neuromuscular paralysis.
Use Principles:
Streptomycin (TCs) ELISA Kit is an indirect competitive enzyme-labeled immunoassay. The Streptomycin antigen is precoated on the wells. The precoated antigen compete the Streptomycin antibody (antibody solution) with Streptomycin in the sample, anti- Streptomycin antibody binds to the Streptomycin-HRP enzyme conjugate. Then pipette the substrate solutions to the wells to convert the color.
The color of unknown samples is compared to the color of the standards and the Streptomycin concentration of the samples is derived.
Manufacturer | Meizheng |
Order No. | ME10A |
Analyte | Streptomycin (TCs) |
Sample Type | Animal tissue, seafood and egg, etc. |
Methodology | Indirect competitive enzyme-labeled immunoassay. |
Packaging | 96 Wells |
Storage | The kits should be stored at a dry place away from the sunlight and the storage temperature is 2-8˚C. DO NOT FREEZE! |
Shelf life | The validity for this kit is 12 months |
Lead time | Shipped within 5-12 working days. |
Cross Reactivity | Streptomycin…………………………………100% Dihydrostreptomycin Sulphate……………100% Kanamycin………………………………<0.01% Gentamycin………………………………<0.01% |
Calculate Result | Analyze the result by using the software |
Sensitivity | 0.2ppb |
Limit of detection | Tissues…………………………………………10ppb |
Percent Recovery, % | Tissues……………………………………90±15% |
Precision (CV %): | Intra-lab assay: CV%≤10% |
Provided Materials and Reagent
Component | 96 wells |
Antigen coated plate | 12 test strips of 8 wells each |
6 vials of standard | 1.5mL each |
High concentration standard (1ppm) | 1.5mL |
TCs Enzyme Conjugate | 6mL |
TCs Antibody Solution | 6mL |
Substrate A | 6mL |
Substrate B | 6mL |
Concentrated Wash Buffer (10×) | 40mL |
Package Insert | 1 |
Testing Report | 1 |
Plate Cover Sheet | 2 |
Note:The concentrations of the standards are 0ppb, 0.2ppb, 0.6ppb, 1.8ppb, 5.4ppb and 16.2ppb.
Materials Required But Not Provided
- Devices:
—- Microwell plate Reader (450nm/630nm)
—- Homogenizer
—- Oscillator
—- Vortex
—- Centrifuge
—- Balance (sensibility: 0.01g)
—- Transfer pipette: 10mL
—- Aurilave
—- Centrifuge tube: 5mL/7mL, 50mL
—- Micropipette: Single channel pipet (10µL-100µL, 100µL-1000µL)
Multi-channel pipet (30µL-300µL)
- Reagent:
—- Deionized water
—- Sodium carbonate anhydrous (AR)
—- Sodium bicarbonate (AR)
—- Concentrated sulfuric acid (18 mol/L)
Note: The pictures shown are sample product pictures.