Search

In Stock

Imidacloprid Rapid Test Cassette for Fruits and Vegetables

【Scope of Application】

Vegetables, fruits (Please check the sample dilution table below. Other sample items not listed, it has not been verified by experiments.)

Order No.: MK185A1EZ

Flyer-Company Overview

【Intended Use】

Imidacloprid Rapid Test Cassette can determine a qualitative level for the presence of Imidacloprid and is intended for use in vegetable and fruit products. This method is suitable for the rapid on-site test for enterprises, testing institutions and supervision departments.

【Use Principle】

Imidacloprid Rapid Test Cassette is an indirect competitive immunoassay. The test substance in the test samples compete the gold-labeled antibodies with the compete antigens on test line (T line), which affect the color developing of T line.

【Limit of Detection】 (mg/kg=ppm)

0.05-5mg/kg (Please check the sample dilution table below)

【Detection Time】

Small batch per group with 6 samples: ≤ 15 mins

【Materials Supplied】

  1. Imidaclopridrapid test cassettes + microwells (10 Tests per box)
  2. Disposable droppers (10 per box)
  3. Sample diluting buffer (2×50mL per box)
  4. 2mL Centrifuge tube (10 per box)
  5. Package Insert (1 piece per box)

【Materials Required But Not Provided】

  1. Scissors
  2. Balance (0.1g)
  3. Centrifuge tube (50mLor 15mL)
  4. Vortex
  5. Pipette (20-200µL/100-1000µL)

 Note: The pictures shown are sample product pictures.

For the actual product, please check Provided Materials and Reagent or consult the sales manager.

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Dairy Lactoperoxidase Test Kit

Order No.: EC0189Lactoperoxidase (LPO) is a peroxidase naturally existing in milk. With the presence of hydrogen peroxide, it is capable of oxidizing thiocyanate ions to produce products with broad antimicrobial activity. Lactoperoxidase has an important role in the dairy cattle immune system. Lactoperoxidase is one of the most heat-stable enzymes found in milk. Pasteurization cannot deactivate it completely. Ultra-high-temperature processing will deactivate it completely. Hence, LPO is an internal index for monitoring and evaluating heat process intensity, testing the LPO activity level has been widely used in dairy production industry.During the heat treatment of milk processing, the level heat intensity is related to the nutritional value of milk. By testing the LPO activity in milk, the nutritional value in the sample can be determined. High volume LPO indicates the milk kept most of its nutrients.Lactoperoxidase Test Kit uses colrimetry, can quickly quantitate the LPO activity level efficiently.

Immunoaffinity Column for Mycotoxin Zearalenone

The immunoaffinity column can selectively adsorb zearalenone from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC or LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Immunoaffinity columns can be used in combination with HPLC/LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0525B 

 

Back to Top
Product has been added to your cart