Microfast® Aerobic Count Plate (AC) AOAC Validated

MicroFast® Aerobic Count Plate (AC) is designed to determine total aerobic bacteria populations. The plate contains prefabricated type of medium, cold water gel and indicator (TTC). It is intended for the aerobic count test for food and environment.

Brochure-Microbiology Test. PDF

Meizheng Bio-Tech Company Overview. PDF

ManufacturerMeizheng
TrademarkAnticfast®
Order No.LR1001
AnalyteTotal aerobic bacteria
Sample TypeFood and environment.
MethodologyCount plate
Packaging25 Tests
Shelf life18 months
Lead timeShipped within 5-12 working days.
Inoculation1mL/piece
Culture temperature35℃±1℃
Culture time 48h±2h
InterpretationCount red colonies
Storage2℃-8℃, keep away from light
ApplicationIt is intended for the aerobic count test for food and environment.

Storage

  1. When unopened, the best storage temperature is 2℃- 8℃, and it is used up within the shelf life.
  2. In a high humidity environment, please restore the test piece to room temperature before use.
  3. After unsealing, it is necessary to fold the package bag twice, then stick it with adhesive tape or seal it with a sealing clip, store it in the dark at 2℃- 8℃, and use it up within one month.
  4. When transporting or short-term storage, just leave the count plate at room temperature.

Precautions

  1. The count plate should be stacked upwards and no more than 20 pieces during the incubation.
  2. Count plate may contain microorganisms that may be a potential biohazard. Follow current industry standards for disposal.
  3. Keep the count plate away from ultraviolet, direct sunlight and fluorescent lamp.
  4. Do not use the polluted count plate.
  5. If the pH of the test sample is too high or too low, it will affect the accuracy of the test results.
  6. When uncover the film, do not touch the culture area of the medium.
  7. When there are too many bacteria, it will affect the detection of positive strains.
  8. The count plate may show a few needle-like black spots, which is normal and does not affect the interpretation of the target strain.
  9. If the sample is viscous, diffusion can be aided manually.
Quantity

1-10, 11-100, 101-1000, 1001-10000

Bestsellers

Aflatoxin B1 Quantitative Rapid Lateral Flow Test Kit

The kit is a lateral flow immunochromatographic assay that determines a quantitative level for the presence of aflatoxin B1 and is intended for use in nuts, grain and feed. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview. PDF

Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Milk Comb Rapid Test Kit

The Neomycin/Paromomycin, Kanamycin, Gentamicin and Spectinomycin Rapid Test Kit is a lateral flow assay that determines a qualitative level for the presence of neomycin/ paromomycin, kanamycin, gentamicin and spectinomycin antibiotic residues in raw cow’s milk.Brochure-Dairy Test. PDFMeizheng Bio-Tech Company Overview. PDF

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for Aflatoxin B1,B2,G1,G2

The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC or LC-MS/MS analysis.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-noise ratio  and improve the accuracy of the detection method.

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Grains and Feed Mycotoxin Fumonisins Quantitative Rapid Test Kit

The kit is a lateral flow immunochromatographic assay that determines a qualitative level for the presence of fumonisins and is intended for use in grains, feed materials and feed products. This method is suitable for the rapid on-site test.Brochure-Grains & Feed Test. PDFMeizheng Bio-Tech Company Overview-V2022-1

Animal Tissue Qualitative or Quantitative Gentamicin ELISA Test Kit

Qualitative or quantitative analysis of gentamicin in animal tissue (chicken, pork, fish, shrimp,etc).Order No.: ME38AER

 

Back to Top
Product has been added to your cart