Showing 25–36 of 46 results
Immunoaffinity Column for Mycotoxin Aflatoxins Total B1,B2,G1,G2,M1,M2
The immunoaffinity column can selectively adsorb aflatoxins (B1, B2, G1, G2, M1, M2) from the sample solution, thereby purifying the sample. The purified sample solution can then be directly used for HPLC analysis.Affinity columns can be used in combination with HPLC to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.This affinity column can be used for the extraction and purification of aflatoxins (B1, B2, G1, G2, M1, M2) in samples.Order No.: HCM0250BPackage: 50T
Immunoaffinity Column for Citrinin
Order No.: HCM2125B
Immunoaffinity Column for Mycotoxin Citrinin
Order No.: HCM2150B
Immunoaffinity Column for Deoxynivalenols (DON/15-ADON)
Order No.: HCM8125BProduct Properties: DON: 2000ng; 15-A-DON: 2000ngSpecification: 3mL,25T
Immunoaffinity Column for Deoxynivalenols (DON/3-ADON/15-ADON)
The immunoaffinity column can selectively adsorb Deoxynivalenol (Vomitoxin,DON),3-acetyldeoxynivalenol,(3-ADON),15-acetyldeoxyniv alenol (15-ADON), and has a highly targeted purification effect. Samples that have passed through the column for purification may be used in HPLC, LC-MS/MS and other devices for analysis after concentrating with nitrogen gas.Affinity columns can be used in combination with HPLC or LC-MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM3025B
Immunoaffinity Column for Mycotoxin Deoxynivalenols (DON/15-ADON)
Order No.: HCM8150BProduct Properties: DON: 2000ng; 15-A-DON: 2000ngSpecification: 3mL, 50T
Immunoaffinity Column for Fumonisins B1,B2,B3
The immunoaffinity column can selectively adsorb fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for LC- MS/MS analysis after concentrating with nitrogen gas and resuspended or for HPLC analysis after derivatization.Affinity columns can be used in combination with HPLC or LC- MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0825BSpecification: 3mL,25T, 5000ng
Immunoaffinity Column for Mycotoxin Fumonisins B1,B2,B3
The immunoaffinity column can selectively adsorb fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for LC- MS/MS analysis after concentrating with nitrogen gas and resuspended or for HPLC analysis after derivatization.Affinity columns can be used in combination with HPLC or LC- MS/MS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0850BSpecification: 3mL,50TComposition: 5000ng
Immunoaffinity Column for Mycotoxin Ochratoxin A
The immunoaffinity column can selectively adsorb Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC analysis or for LC-MS/MS analysis after being concentrated with nitrogen gas and resuspended.Affinity columns can be used in combination with HPLC to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0725BPackage: 3mL,50TCoposition: 100 ng
Immunoaffinity Column for Ochratoxin A
The immunoaffinity column can selectively adsorb Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC analysis or for LC-MS/MS analysis after being concentrated with nitrogen gas and resuspended.Affinity columns can be used in combination with HPLC to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.Order No.: HCM0725BPackage: 3mL,25TComposition: 100ng