Search

Meizheng supplies IAC for Aflatoxins B1,B2,G1,G2; IAC for Aflatoxins Total B1,B2,G1,G2,M1,M2; IAC for Aflatoxin B1, IAC for Zearalenone, IAC for Deoxynivalenol, IAC for Deoxynivalenols (DON/3-ADON/15-ADON), IAC for Ochratoxin A, IAC for Fumonisins B1,B2,B3; IAC for T-2 Toxin, IAC for Citrinin, IAC 2-in-1 Aflatoxin B1/Deoxynivalenol, IAC 2-in-1 Aflatoxin (B1,B2,G1,G2,M1,M2)/Ochratoxin A and so on.

Bestsellers in Pre-treatment

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Immunoaffinity Column 4-in-1 Comb Aflatoxin B1, Zearalenone, Deoxynivalenol and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin B1, Zearalenone (ZEN), Deoxynivalenol (DON) and Ochratoxin A(OTA) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3225B/HCM3250B

Immunoaffinity Column for Mycotoxins 6-in-1 Combo

The immunoaffinity column can simultaneously adsorb Aflatoxin (AFT B1, AFT B2, AFT G1, AFT G2, AFT M1, AFT M2), Zearalenone(ZEN) and its derivatives (ZAN, α-ZOL, β-ZOL, α-ZAL, β-ZAL), Deoxynivalenol (DON) and 15-Acetyldeoxynivalenol (15-ADON), Ochratoxin (OTA), T-2 toxin and HT-2 toxin, fumonisin (FB1, FB2, FB3) from the sample extract solution, thereby having a highly targeted purification effect on the above 20 toxins of the six major types, and the samples that have be purified after passing through the column can be used in LC-MS (LC-MS/MS) analysis.Order No.: HCM3110

Showing 1–12 of 47 results

Sort by

Aflatoxin M1 Immunoaffinity Column

Order No.: QC0068,QC0069,QC0131,QC0071Column Capacity:100 ngVolumn: 3mLPackage: 25/50T 

Immunoaffinity Column 3-in-1 Comb Aflatoxin B1, Zearalenone and T-2 Toxin

The immunoaffinity column can selectively adsorb aflatoxin B1, Zearalenone and T-2 Toxin from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM6525B/HCM6550B

Immunoaffinity Column 4-in-1 Comb Aflatoxin B1, Zearalenone, Deoxynivalenol and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin B1, Zearalenone (ZEN), Deoxynivalenol (DON) and Ochratoxin A(OTA) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3225B/HCM3250B

Immunoaffinity Column for 2-in-1 Aflatoxins (B1,B2,G1,G2) and Ochratoxin A

The immunoaffinity column can selectively adsorb aflatoxin (B1, B2, G1, G2) and Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample  solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.Order No.: HCM3725B/HCM3750BProduct Properties: AFT B1/B2/G1/G2 300ng, OTA 100ngSpecifications: 3mL,25T/50T

Immunoaffinity Column for 2-in-1 Comb Zearalenone and Fumonisins

The immunoaffinity column can selectively adsorb zearalenone (ZEN) and fumonisin (FB1, FB2, FB3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the affinity column can be directly used for HPLC analysis or for LC-MS/MS analysis after concentrating with nitrogen gas and resuspended. 

 

Back to Top
Product has been added to your cart